    A method to expedite data acquisition for multiple spatial-temporal analyses of tissue perfusion by contrast-enhanced ultrasound

  • Author

    Hansen, Christian ; Hüttebräuker, Nils ; Wilkening, Wilko ; Ermert, Helmut

  • Author_Institution
    Inst. for High Freq. Eng., Ruhr-Univ., Bochum
  • Volume
    56
  • Issue
    3
  • fYear
    2009
  • fDate
    3/1/2009 12:00:00 AM
  • Firstpage
    507
  • Lastpage
    519
  • Abstract
    For semiquantitative analyses of tissue perfusion using contrast-enhanced ultrasound the acquisition and processing of time intensity curves (TIC) is required. These TICs can be computed for each pixel of an image plane, yielding parametric images of classification numbers like "blood volume" and "flow rate." The expenditure of time for data acquisition and analysis typically limits semiquantitative perfusion imaging to a single image plane in 2-D. 3-D techniques, however, provide a higher diagnostic value since more information (e.g., of an entire lesion) is obtained. Moreover, spatial compounding, being a 2-D-technique where an object is imaged from different viewing angles, is known to improve image quality by reducing artifacts and speckle noise. Both techniques, 3-D and compounding, call for optimized acquisition and processing of TICs in several image planes (3-D) or in several (overlapping) sections of the same image plane (compounding) to decrease the time needed for data acquisition. Here, an approach of interleaved imaging is presented which is applicable, among others, to contrast perfusion imaging using the replenishment method. The total acquisition time is decreased by sequentially scanning image planes twice for short time spans-first, immediately after microbubble destruction to record the initial rise of the TICs, and second, a sufficient time thereafter to assess final values of the TIC. Data from both periods are combined to fit a model function from which parameters are extracted such as perfusion rate and blood volume. This approach was evaluated by in vitro measurements on a perfusion-mimicking phantom for both, individual images such as would be used for volume reconstruction in 3-D and compound images obtained from full angle spatial compounding (FASC, 360deg). An error analysis is conducted to derive the deviation of the extracted parameters of the proposed method compared with the conventional one. These deviations are entailed by a reduct- on in acquisition time of the proposed method, which can be adjusted by several parameters, depending on the prevailing flow. Optimization strategies are proposed to find optimal values for those settings.
  • Keywords
    biological tissues; biomedical ultrasonics; data acquisition; error analysis; haemorheology; image enhancement; medical image processing; phantoms; spatiotemporal phenomena; speckle; blood volume; compounding; contrast-enhanced ultrasound; data acquisition; error analysis; full angle spatial compounding; image classification; image quality; interleaved imaging; microbubble destruction; perfusion rate; phantom; replenishment method; spatial-temporal analysis; speckle noise; time intensity curves; tissue perfusion; volume reconstruction; Blood; Data acquisition; Data analysis; Image analysis; Image quality; Information analysis; Lesions; Pixel; Speckle; Ultrasonic imaging; Algorithms; Contrast Media; Image Enhancement; Models, Theoretical; Perfusion; Phantoms, Imaging; Time Factors; Ultrasonography;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2009.1068
  • Filename
    4816059