DocumentCode :
1247663
Title :
Second-order compensated bandgap reference with convex correction
Author :
Avoinne, C. ; Rashid, Taimur ; Chowdhury, V. ; Rahajandraibe, W. ; Dufaza, C.
Author_Institution :
L2MP, Polytech. Marseille, France
Volume :
41
Issue :
5
fYear :
2005
fDate :
3/3/2005 12:00:00 AM
Firstpage :
276
Lastpage :
277
Abstract :
A correction technique for second-order temperature variation of bandgap voltage references (BGR) is presented. It consists of adding a convex curve with a simple circuit to the standard bell curve of a first-order BGR. The temperature coefficient of the new BGR is as low as 1 ppm//spl deg/C.
Keywords :
error compensation; reference circuits; bandgap voltage references; bell curve; compensated bandgap reference; convex correction; convex curve; second-order bandgap reference; second-order temperature variation;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:20057071
Filename :
1406596
Link To Document :
بازگشت