• DocumentCode
    1249780
  • Title

    Correlation of calibration equations for test fixtures

  • Author

    Zhu, Ning Hua ; Auracher, Franz

  • Author_Institution
    Siemens Corp. Technol., Munich, Germany
  • Volume
    47
  • Issue
    10
  • fYear
    1999
  • fDate
    10/1/1999 12:00:00 AM
  • Firstpage
    1949
  • Lastpage
    1953
  • Abstract
    This paper begins from the thru-short-open (TSO) and thru-line-match (TLM) methods to investigate the correlation of the calibration equations of these two methods. The relations among the measurements with the corresponding standards are obtained. It is found that the line standard with zero length can be used instead of ideal open and short, in the case that two test fixtures are symmetrical. For asymmetrical fixtures, the measurements with the standards line, open and short are related at certain frequencies, and the matched load can be replaced by the line standards. The relations established are used to test short and match standards and analyze the frequency limits of the TSO method. Good agreement between theory and experiment is obtained. It is found that the TSO method becomes very poor when the insertion phase of the thru standard is near nπ/4, and this method has a lower frequency limit. The TLM method is found unsuitable for calibrating asymmetrical fixtures
  • Keywords
    S-parameters; calibration; microwave measurement; network analysers; test equipment; asymmetrical fixtures; calibration equations; frequency limit; frequency limits; insertion phase; line standard; test fixtures; thru-line-match method; thru-short-open method; Calibration; Equations; Fixtures; Frequency measurement; Helium; Measurement standards; Microwave measurements; Scattering parameters; Testing; Transmission lines;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/22.795068
  • Filename
    795068