DocumentCode :
1249780
Title :
Correlation of calibration equations for test fixtures
Author :
Zhu, Ning Hua ; Auracher, Franz
Author_Institution :
Siemens Corp. Technol., Munich, Germany
Volume :
47
Issue :
10
fYear :
1999
fDate :
10/1/1999 12:00:00 AM
Firstpage :
1949
Lastpage :
1953
Abstract :
This paper begins from the thru-short-open (TSO) and thru-line-match (TLM) methods to investigate the correlation of the calibration equations of these two methods. The relations among the measurements with the corresponding standards are obtained. It is found that the line standard with zero length can be used instead of ideal open and short, in the case that two test fixtures are symmetrical. For asymmetrical fixtures, the measurements with the standards line, open and short are related at certain frequencies, and the matched load can be replaced by the line standards. The relations established are used to test short and match standards and analyze the frequency limits of the TSO method. Good agreement between theory and experiment is obtained. It is found that the TSO method becomes very poor when the insertion phase of the thru standard is near nπ/4, and this method has a lower frequency limit. The TLM method is found unsuitable for calibrating asymmetrical fixtures
Keywords :
S-parameters; calibration; microwave measurement; network analysers; test equipment; asymmetrical fixtures; calibration equations; frequency limit; frequency limits; insertion phase; line standard; test fixtures; thru-line-match method; thru-short-open method; Calibration; Equations; Fixtures; Frequency measurement; Helium; Measurement standards; Microwave measurements; Scattering parameters; Testing; Transmission lines;
fLanguage :
English
Journal_Title :
Microwave Theory and Techniques, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9480
Type :
jour
DOI :
10.1109/22.795068