Abstract :
The results of a research program carried out to quantify the reliability of joint moldings for dc operation in submarine telecommunications cables are reported. The region of the bulk insulation most at risk of electrical failure has been identified as the amalgamation zone of the molding, which is believed to be associated with additional electrical stress-enhancing defects present at the conductor-insulator interface. In addition to factory tests implemented to eliminate moldings with severely hazardous defects, a quality assurance sampling test procedure is proposed to optimize the manufacturing quality
Keywords :
cable insulation; cable testing; insulation testing; quality control; reliability; submarine cables; DC operation; amalgamation zone; bulk insulation; conductor-insulator interface; electrical failure; electrical reliability; electrical stress-enhancing defect; joint molding; manufacturing quality; quality assurance sampling test; submarine telecommunications cable; Cable insulation; Manufacturing; Materials testing; Optical amplifiers; Production facilities; Reliability engineering; Repeaters; System testing; Telecommunication network reliability; Underwater vehicles;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/94.590853
Filename :
590853
Link To Document :
بازگشت