DocumentCode :
1251378
Title :
Experience with Large Hydro-Generators at Grand Coulee
Author :
Moore, V.A.
Author_Institution :
Canadian General Electric Co., Ltd., Peterborough, ON, Canada
Issue :
10
fYear :
1983
Firstpage :
25
Lastpage :
25
Abstract :
The design and construction of the three 826 MV??A hydro-generators for the Grand Coulee Third Power Plant represents a significant achievement. A number of factors conspired to create a situation wherein local contact occurred between the stator and rotors of one unit. This paper outlines the events leading up to this incident, describes investigative work, and remedial measures taken to reestablish the intended design parameters.
Keywords :
Heating; Instruments; Power generation; Q measurement; Rotors; Stators; Telemetry; Temperature measurement; Temperature sensors; Testing;
fLanguage :
English
Journal_Title :
Power Engineering Review, IEEE
Publisher :
ieee
ISSN :
0272-1724
Type :
jour
DOI :
10.1109/MPER.1983.5520068
Filename :
5520068
Link To Document :
بازگشت