DocumentCode :
1252498
Title :
A projector/backprojector with slice-to-slice blurring for efficient three-dimensional scatter modeling
Author :
Zeng, Gengsheng L. ; Bai, Chuanyong ; Gullberg, Grant T.
Author_Institution :
Dept. of Radiol., Utah Univ., Salt Lake City, UT, USA
Volume :
18
Issue :
8
fYear :
1999
Firstpage :
722
Lastpage :
732
Abstract :
Scatter correction is an important factor in single photon emission computed tomography (SPECT). Many scatter correction techniques, such as multiple-window subtraction and intrinsic modeling with iterative algorithms, have been under study for many years. Previously, the authors developed an efficient slice-to-slice blurring technique to model attenuation and system geometric response in a projector/backprojector pair, which was used in an ML-EM algorithm to reconstruct SPECT data. This paper proposes a projector/backprojector that models the three-dimensional (3-D) first-order scatter in SPECT, also using an efficient slice-to-slice blurring technique. The scatter response is estimated from a known nonuniform attenuation distribution map. It is assumed that the probability of detection of a first-order scattered photon from a photon that is emitted in a given source voxel and scattered in a given scatter voxel is proportional to the attenuation coefficient value at that voxel. Monte Carlo simulations of point sources and an MCAT torso phantom were used to verify the accuracy of the proposed projector/backprojector model. An experimental Jaszczak torso/cardiac phantom SPECT study was also performed. For a 64×64×64 image volume, it took 8.7 s to perform each iteration per slice on a Sun ULTRA Enterprise 3000 (167 MHz, 1 Gbyte RAM) computer, when modeling 3-D scatter, attenuation, and system geometric response functions. The main advantage of the proposed method is its easy implementation and the possibility of performing reconstruction in clinically acceptable time.
Keywords :
Monte Carlo methods; gamma-ray scattering; image reconstruction; iterative methods; medical image processing; modelling; single photon emission computed tomography; 1 Gbyte; 167 MHz; 8.7 s; MCAT torso phantom; Monte Carlo simulations; clinically acceptable time; efficient three-dimensional scatter modeling; experimental Jaszczak torso/cardiac phantom SPECT study; first-order scattered photon; medical diagnostic imaging; nonuniform attenuation distribution map; nuclear medicine; point sources; projector/backprojector; scatter voxel; slice-to-slice blurring; Attenuation; Electromagnetic scattering; Image reconstruction; Imaging phantoms; Iterative algorithms; Particle scattering; Single photon emission computed tomography; Solid modeling; Sun; Torso; Computer Simulation; Image Processing, Computer-Assisted; Phantoms, Imaging; Tomography, Emission-Computed, Single-Photon;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.796285
Filename :
796285
Link To Document :
بازگشت