Abstract
Phase contrast magnetic resonance imaging (MRI) can provide in vivo myocardial velocity field measurements. These data allow densely spaced material points to be tracked throughout the whole heart cycle using, for example, the Fourier tracking algorithm. To process the tracking results for myocardial deformation and strain quantification, the authors developed a method that is based on fitting the tracking results to an appropriate local deformation model. They further analyzed the accuracy and precision of the method and provided performance predictions for several local models. In order to validate the method and the theoretical performance analysis, the authors conducted controlled computer simulations and a phantom study. The results agreed well with expectations. Human heart data were also acquired and analyzed, and provided encouraging results. At the signal-to-noise ratio (SNR) level and spatial resolution expected in clinical settings, the study predicts strain quantification accuracy and precision that may allow the technique to become a practical and powerful noninvasive approach for the study of cardiac function, although clinically acceptable data acquisition strategies for three-dimensional (3-D) data are still a challenge.
Keywords
biomechanics; biomedical NMR; biomedical measurement; cardiology; medical image processing; muscle; strain measurement; velocity measurement; Fourier tracking algorithm; cardiac function study method; cardiac magnetic resonance imaging; clinically acceptable data acquisition strategies; controlled computer simulations; deformation gradient estimation; densely spaced material points; human heart data; in vivo myocardial velocity field measurements; medical diagnostic imaging; noninvasive approach; phantom study; phase contrast magnetic resonance imaging; signal-to-noise ratio; spatial resolution; whole heart cycle; Heart; In vivo; Magnetic field induced strain; Magnetic field measurement; Magnetic materials; Magnetic resonance imaging; Myocardium; Performance analysis; Phase measurement; Velocity measurement; Aortic Stenosis, Subvalvular; Computer Simulation; Humans; Image Processing, Computer-Assisted; Magnetic Resonance Imaging, Cine; Myocardial Contraction; Phantoms, Imaging; Reproducibility of Results;
fLanguage
English
Journal_Title
Medical Imaging, IEEE Transactions on
Publisher
ieee
ISSN
0278-0062
Type
jour
DOI
10.1109/42.650880
Filename
650880
Link To Document