    On the accommodation of coolant flow paths in high density packaging

  • Author

    Nakayama, Wataru

  • Author_Institution
    Hitachi Ltd., Tokyo, Japan
  • Volume
    13
  • Issue
    4
  • fYear
    1990
  • fDate
    12/1/1990 12:00:00 AM
  • Firstpage
    1040
  • Lastpage
    1049
  • Abstract
    An analytical study was conducted to determine a balance between the switching speed of logic gates and the average wiring distance in the system on the basis of the heat removal capability of the coolant. One of the models consists of a row of gate-carrying cards flanked by side boards having networks to complete three-dimensional wiring. The gates are cooled by forced convection of FC-77 or water. It is shown that the wiring distance is seriously increased by the need to make room for coolant channels within the system. As a model of a single-card system, a square array of logic gates cooled by impinging liquid jets is considered. It is concluded that the space requirement of coolant flows could set the upper bound for the density of logic gate packing. It is pointed out that more heat transfer data are needed to complete a tradeoff study
  • Keywords
    convection; cooling; heat sinks; logic arrays; modules; packaging; FC-77; H2O; average wiring distance; coolant channels; coolant flow paths; forced convection; gate-carrying cards; heat removal capability; heat transfer; high density packaging; impinging liquid jets; logic gates; packing; side boards; single-card system; square array of logic gates; switching speed; three-dimensional wiring; water; Coolants; Electronic packaging thermal management; Information processing; Kelvin; Logic arrays; Logic gates; Surface resistance; Thermal conductivity; Wire; Wiring;
  • fLanguage
    English
  • Journal_Title
    Components, Hybrids, and Manufacturing Technology, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0148-6411
  • Type

    jour

  • DOI
    10.1109/33.62546
  • Filename
    62546