• DocumentCode
    1257465
  • Title

    Model-based leakage detection in a pulverized coal injection vessel

  • Author

    Johansson, Andreas ; Medvedev, Alexander

  • Author_Institution
    Lulea Univ. of Technol., Sweden
  • Volume
    7
  • Issue
    6
  • fYear
    1999
  • fDate
    11/1/1999 12:00:00 AM
  • Firstpage
    675
  • Lastpage
    682
  • Abstract
    A method for detecting and isolating incipient leakages in the valves of a pulverized coal injection vessel for a blast furnace process is presented. Nonlinear physical gray-box models of the plant are developed. Values of the unknown parameters are estimated by identification. Observers are constructed for these models and the residuals are used in a generalized likelihood ratio test. The method is successfully tested with real leakages intentionally introduced in the plant
  • Keywords
    fault diagnosis; furnaces; leak detection; observers; parameter estimation; blast furnace; fault detection; gas leakage detection; identification; likelihood ratio test; observers; parameter estimation; pulverized coal injection vessel; valves; Blast furnaces; Electrical fault detection; Fault detection; Leak detection; Nitrogen; Observers; Powders; Pressure control; Testing; Valves;
  • fLanguage
    English
  • Journal_Title
    Control Systems Technology, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1063-6536
  • Type

    jour

  • DOI
    10.1109/87.799668
  • Filename
    799668