DocumentCode :
1259963
Title :
Applying a metric space to design a primary transducer of electromagnetic flow meter for open channels
Author :
Michalski, Andrzej ; Piotrowski, Wieslaw
Author_Institution :
Inst. of the Theor. of Electr. Eng. & Electr. Measurements, Warsaw Univ. of Technol., Poland
Volume :
51
Issue :
1
fYear :
2002
fDate :
2/1/2002 12:00:00 AM
Firstpage :
14
Lastpage :
17
Abstract :
This paper deals with a problem of selecting an appropriate liquid level as a parameter in designing the exciting coil of the electromagnetic (EM) flow meter. The influence of variable liquid level on the transfer function of the EM flow meter is explained. The method of selecting the optimal liquid level utilizing the metric spaces is described. Some examples of metrics and the results of numerical calculations are presented. With this method, the transfer function of the EM flow meter can be significantly improved
Keywords :
coils; electric sensing devices; electromagnetic devices; flowmeters; transducers; EM flowmeters; electromagnetic flow meter; electromagnetic flowmeters; exciting coil; flow measurement; matrix factorization; metric space applications; primary transducer; transfer function; variable liquid level; Coils; Electrodes; Electromagnetic measurements; Extraterrestrial measurements; Fluid flow measurement; Magnetic field measurement; Magnetic flux density; Shape; Transducers; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.989888
Filename :
989888
Link To Document :
بازگشت