Title : 
High precision measurement of DC voltage ratios from 20 V/10 V to 1000 V/10 V
         
        
            Author : 
Zhang, Xiuzeng ; Qie, Jiaping ; Zhang, Lili ; Shao, Haiming
         
        
            Author_Institution : 
Electromagn. Div., Nat. Inst. of Metrol., Beijing, China
         
        
        
        
        
            fDate : 
2/1/2002 12:00:00 AM
         
        
        
        
            Abstract : 
This paper presents a new method of calibrating de voltage ratios from 20 V: 10 V to 1000 V: 10 V. A new battery-powered differential voltage detector has been developed to reduce the uncertainty of the measurement system. An absolute self-calibration process was used and traceability to a voltage ratio standard is not necessary. The uncertainties of dc voltage ratios (20 V to 1000 V): 10 V were less than 2 × 10-7
         
        
            Keywords : 
calibration; stability; voltage dividers; voltage measurement; 1000 V to 10 V; 1000 to 10 V; 20 V to 10 V; 20 to 10 V; DC voltage divider; DC voltage ratio; absolute self-calibration; battery-powered differential voltage detector; reference divider; traceability; uncertainties; uncertainty; voltage ratio standard; Calibration; Capacitors; Circuits; Detectors; Preamplifiers; Resistors; Sampling methods; Stability; Temperature; Voltage measurement;
         
        
        
            Journal_Title : 
Instrumentation and Measurement, IEEE Transactions on