    Discussion at Pittsfield: Notes on the use of a radio-frequency voltmeter

  • Author

    Goodwin

  • Author_Institution
    Pittsfield, Mass.
  • Volume
    46
  • Issue
    10
  • fYear
    1927
  • Firstpage
    1115
  • Lastpage
    1116
  • Abstract
    L. T. Wilson: It has been mentioned that this meter takes from 2 to 8 milliamperes, and that a displacement current flows between the shields of the same order of magnitude. It was not specified in that statement that, that charging current is of the same order of magnitude as this 2 to 8 milliamperes only at 1,000,000 cycles. Of course, at any frequency lower than that, the charging current is proportionately lower, and down at very low frequencies, it is entirely negligible.