DocumentCode
126654
Title
CSRH-II analog receiver system stability designing and testing
Author
Lihong Geng ; Yihua Yan ; Qinghui Song ; Lihui Wei ; Zhijun Chen ; Wei Wang ; Linjie Chen ; Donghao Liu ; Cang Su ; Yunying Jiang
Author_Institution
Nat. Astron. Obs., Beijing, China
fYear
2014
fDate
16-23 Aug. 2014
Firstpage
1
Lastpage
4
Abstract
Analog receiver is one of the key parts of the Chinese Spectral Radioheliograph (CSRH). Analog receiver CSRH-II is used to amplify, transmitting and down converting the solar emission signal from 2GHz to 15GHz. Its system stability is much important for achieving the best quality solar images. CSRH-II system specifications set high requirements for the analog receiver system´s stability designing and testing. In this paper, CSRH-II analog receiver system specification requirement, designing and testing will be discussed and presented.
Keywords
receivers; testing; thermal analysis; thermal stability; CSRH-II analog receiver system stability designing; CSRH-II analog receiver system stability testing; Chinese spectral radioheliograph; frequency 2 GHz to 15 GHz; solar emission signal; solar images; Receivers; Stability analysis; Temperature control; Temperature measurement; Testing; Thermal analysis; Thermal stability;
fLanguage
English
Publisher
ieee
Conference_Titel
General Assembly and Scientific Symposium (URSI GASS), 2014 XXXIth URSI
Conference_Location
Beijing
Type
conf
DOI
10.1109/URSIGASS.2014.6930020
Filename
6930020
Link To Document