DocumentCode
1267211
Title
Application of a new automatic gauge control system for the tandem cold mill
Author
Tezuka, Tomoyuki ; Yamashita, Takashi ; Sato, Takumi ; Abiko, Youji ; Kanai, Tomohiro ; Sawada, Mamoru
Author_Institution
Power & Ind. Syst., Toshiba Corp., Tokyo, Japan
Volume
38
Issue
2
fYear
2002
Firstpage
553
Lastpage
558
Abstract
In July 2000, a new automatic gauge control (AGC) system was successfully installed at the Kakogawa Works, Kobe Steel, Ltd., Hyogo, Japan. The new AGC system consists of two functions: multivariable AGC based on mass flow thickness; and roll eccentricity control. The multivariable AGC is designed using inverse linear quadratic theory, a type of optimal control theory, and controls both thickness and tension. Repetitive control theory is applied to roll eccentricity control as roll eccentricity is a periodic disturbance related to the rotational angle of the rolls. The new AGC system has contributed to improved thickness accuracy and stable rolling. In this paper, details of the new AGC system are described and the application results are shown
Keywords
force control; linear quadratic control; multivariable control systems; process control; rolling mills; steel industry; thickness control; automatic gauge control system; inverse linear quadratic theory; mass flow thickness; multivariable AGC; optimal control theory; repetitive control theory; roll eccentricity control; tandem cold mill; tension control; thickness control; Automatic control; Control systems; Control theory; Fluctuations; Milling machines; Optimal control; Steel; Strips; Thickness control; Weight control;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/28.993178
Filename
993178