    Cell Death Induced by Subnanosecond Pulsed Electric Fields at Elevated Temperatures

  • Author

    Camp, J. Thomas ; Jing, Yu ; Zhuang, Jie ; Kolb, Juergen F. ; Beebe, Stephen J. ; Song, Jiahui ; Joshi, Ravindra P. ; Xiao, Shu ; Schoenbach, Karl H.

  • Author_Institution
    Frank Reidy Res. Center for Bioelectrics, Old Dominion Univ., Norfolk, VA, USA
  • Volume
    40
  • Issue
    10
  • fYear
    2012
  • Firstpage
    2334
  • Lastpage
    2347
  • Abstract
    The rate of trypan blue uptake of liver cancer cells, indicating cell death, when exposed to subnanosecond high electric field pulses, increased strongly when the temperature was raised above 37 °C. The exposure of Hepa 1-6 cells to 2000 pulses of 200 picosecond duration and electric field amplitudes exceeding 80 kV/cm induced cell death in almost 30% of the cells when the temperature was increased to 47 °C for the time of the pulsing. For temperatures at 37 °C and below, the same exposure to pulsed electric fields did not show any measurable effect. Even for the maximum elevated temperature of 47 °C, thermal effects were not found to cause fatalities for the time of exposure, which was, for 2000 pulses at a repetition rate of 7-9 pulses per second, on the order of 5 min. The effect of temperature on the electrical properties of the cell was measured by means of dielectric spectroscopy. The membrane voltages derived from these values were found to be too low to cause electroporation at room temperature. However, the reduced viscosity of the membrane with temperature is likely to reduce the threshold for poration, and together with the effect of multiple pulses, is considered to be the cause for the observed high death rate of the cells. This argument is supported by molecular dynamics simulations which show an increased probability for pore formation with temperature.
  • Keywords
    bioelectric phenomena; biological effects of fields; biothermics; cancer; cellular effects of radiation; molecular dynamics method; Hepa 1-6 cells; cell death; dielectric spectroscopy; electric field amplitudes; electroporation; elevated temperatures; liver cancer cells; membrane voltages; molecular dynamics simulations; pore formation; subnanosecond pulsed electric fields; temperature 47 C; thermal effects; trypan blue uptake; Electrodes; Plasma temperature; Probes; Pulse measurements; Temperature measurement; Temperature sensors; Voltage measurement; Cancer cells; cell death; electroporation; pulsed electric fields; subnanosecond pulses; temperature effects;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.2012.2208202