• DocumentCode
    1269565
  • Title

    Characterization of fluor concentration and geometry in organic scintillators for in situ beta imaging

  • Author

    Tornai, Martin P. ; Hoffman, Edward J. ; MacDonald, Lawrence R. ; Levin, Craig S.

  • Author_Institution
    Div. of Nucl. Med. & Biophys., California Univ., Los Angeles, CA, USA
  • Volume
    43
  • Issue
    6
  • fYear
    1996
  • fDate
    12/1/1996 12:00:00 AM
  • Firstpage
    3342
  • Lastpage
    3347
  • Abstract
    Development of a small area (1-2 cm2) in situ beta imaging device includes optimization of the front end scintillation detector, which is fiber optically coupled to a remote photon detector. Thin plastic scintillation detectors, which are sensitive to charged particles, are the ideal detectors due to the low sensitivity to ambient gamma backgrounds. The light output of a new binary plastic scintillator was investigated with respect to increasing concentrations of the fluor (0.5-2.0% by weight) and varying thickness cylindrical configurations of the intended imaging detector. The fluor had an emission maximum increasing from 431 to 436 nm with increasing fluor concentration. The decay time(s) had two components (0.38 and 1.74 ns). There was an ~20% increase in light output with increasing fluor concentration, measured with both 204Tl betas and conversion electrons from 207 Bi. The highest light output of this new scintillator was measured to be ~30% lower than BC404. Simulations predicted the 1.5 mm scintillator thickness at which light output and energy absorption for ~700 keV electrons (e.g., from 204Tl, 18F) were maximized, which corresponded with measurements. As beta continua are relatively featureless, energy calibration for the thin scintillators was investigated using Landau distributions, which appear as distinct peaks in the spectra. As the scintillators were made thinner, gamma backgrounds were shown to linearly decrease
  • Keywords
    beta-ray detection; biomedical equipment; radioisotope imaging; solid scintillation detectors; 0.38 ns; 1.74 ns; 431 nm; 436 nm; 700 keV; Bi; F; Landau distribution; Tl; ambient gamma backgrounds; charged particles; emission maximum; fiber optically coupling; fluor concentration characterization; front end scintillation detector; gamma backgrounds; imaging detector; in situ beta imaging; light output; medical diagnostic imaging; medical instrumentation; nuclear medicine; organic scintillators; remote photon detector; thin plastic scintillation detectors; varying thickness cylindrical configurations; Electrons; Geometrical optics; Geometry; Optical devices; Optical fiber devices; Optical imaging; Optical sensors; Plastics; Scintillation counters; Solid scintillation detectors;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.552749
  • Filename
    552749