DocumentCode
1269680
Title
Alignment fixture for millimeter waveguide
Author
Kremer, D.P. ; Newell, A.C.
Author_Institution
Nat. Inst. of Stand. & Technol., Boulder, CO, USA
Volume
32
Issue
3
fYear
1990
fDate
6/1/1990 12:00:00 AM
Firstpage
45
Lastpage
48
Abstract
An alignment fixture for handling the precise waveguide connection procedures required in performing gain measurements of millimeter-wave antennas is described. Two versions of the fixture were developed: one for small devices, such as standard gain horns, which can be supported by the fixture, and another for larger devices. These systems, along with a properly-installed flange, can reduce the measurement uncertainty associated with the connection from greater than 1 dB to a few hundredths of a decibel. For measurements in the WR-22 and WR-15 waveguide bands, the overall gain error for millimeter-frequency antenna measurements has decreased from 0.31 dB to 0.10 dB.<>
Keywords
gain measurement; microwave antennas; microwave measurement; waveguide couplers; MM wave antennas; WR-15 waveguide bands; WR-22 waveguide band; alignment fixture; flange; gain error; gain measurements; millimeter waveguide; waveguide connection procedures; Antenna measurements; Fixtures; Flanges; Frequency measurement; Gain measurement; Insertion loss; Loaded antennas; Loss measurement; Millimeter wave measurements; Millimeter wave technology;
fLanguage
English
Journal_Title
Antennas and Propagation Magazine, IEEE
Publisher
ieee
ISSN
1045-9243
Type
jour
DOI
10.1109/74.80527
Filename
80527
Link To Document