• DocumentCode
    1269680
  • Title

    Alignment fixture for millimeter waveguide

  • Author

    Kremer, D.P. ; Newell, A.C.

  • Author_Institution
    Nat. Inst. of Stand. & Technol., Boulder, CO, USA
  • Volume
    32
  • Issue
    3
  • fYear
    1990
  • fDate
    6/1/1990 12:00:00 AM
  • Firstpage
    45
  • Lastpage
    48
  • Abstract
    An alignment fixture for handling the precise waveguide connection procedures required in performing gain measurements of millimeter-wave antennas is described. Two versions of the fixture were developed: one for small devices, such as standard gain horns, which can be supported by the fixture, and another for larger devices. These systems, along with a properly-installed flange, can reduce the measurement uncertainty associated with the connection from greater than 1 dB to a few hundredths of a decibel. For measurements in the WR-22 and WR-15 waveguide bands, the overall gain error for millimeter-frequency antenna measurements has decreased from 0.31 dB to 0.10 dB.<>
  • Keywords
    gain measurement; microwave antennas; microwave measurement; waveguide couplers; MM wave antennas; WR-15 waveguide bands; WR-22 waveguide band; alignment fixture; flange; gain error; gain measurements; millimeter waveguide; waveguide connection procedures; Antenna measurements; Fixtures; Flanges; Frequency measurement; Gain measurement; Insertion loss; Loaded antennas; Loss measurement; Millimeter wave measurements; Millimeter wave technology;
  • fLanguage
    English
  • Journal_Title
    Antennas and Propagation Magazine, IEEE
  • Publisher
    ieee
  • ISSN
    1045-9243
  • Type

    jour

  • DOI
    10.1109/74.80527
  • Filename