DocumentCode
1272217
Title
Active network for correcting impulse-voltage measurements
Author
Liang, X. ; Martens, G.O.
Author_Institution
Dept. of Electr. Eng., Manitoba Univ., Winnipeg, Man., Canada
Volume
135
Issue
7
fYear
1988
fDate
9/1/1988 12:00:00 AM
Firstpage
487
Lastpage
492
Abstract
High-voltage impulse measurements are usually carried out by using a divider system which may distort the impulse. The authors present a method for the correction of the input signal from the distorted output signal by using a wideband active network. The method is demonstrated by several test results. The accuracy analysis of the method is also carried out theoretically. The correction method is simple to apply
Keywords
active networks; broadband networks; high-voltage techniques; signal processing; voltage measurement; waveform analysis; HV impulse measurement; accuracy analysis; correction method; divider system; signal correction;