• DocumentCode
    1276044
  • Title

    Transient behaviour of salient-pole synchronous machines with internal stator winding faults

  • Author

    Wang, X.H. ; Sun, Y.G. ; Ouyang, B. ; Wang, W.J. ; Zhu, Z.Q. ; Howe, D.

  • Author_Institution
    Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
  • Volume
    149
  • Issue
    2
  • fYear
    2002
  • fDate
    3/1/2002 12:00:00 AM
  • Firstpage
    143
  • Lastpage
    151
  • Abstract
    Internal stator winding faults in salient-pole synchronous machines can cause serious damage to a machine and the system to which it is connected. Thus, it is highly desirable to be able to accurately model their transient behaviour and to predict the resulting currents and voltages in order to develop appropriate protection schemes, particularly for high power machines. Based on the multi-loop circuit method, a general mathematical model for a salient-pole synchronous machine with internal faults is established, and subsequently employed to simulate both the steady-state and transient behaviour for three different types of internal fault. Predicted results are validated by experimental measurements
  • Keywords
    electrical faults; stators; synchronous machines; transient analysis; internal faults; internal stator winding faults; mathematical model; multi-loop circuit method; salient-pole synchronous machines; steady-state behaviour; transient behaviour;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings -
  • Publisher
    iet
  • ISSN
    1350-2352
  • Type

    jour

  • DOI
    10.1049/ip-epa:20020068
  • Filename
    997805