DocumentCode
1276044
Title
Transient behaviour of salient-pole synchronous machines with internal stator winding faults
Author
Wang, X.H. ; Sun, Y.G. ; Ouyang, B. ; Wang, W.J. ; Zhu, Z.Q. ; Howe, D.
Author_Institution
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
Volume
149
Issue
2
fYear
2002
fDate
3/1/2002 12:00:00 AM
Firstpage
143
Lastpage
151
Abstract
Internal stator winding faults in salient-pole synchronous machines can cause serious damage to a machine and the system to which it is connected. Thus, it is highly desirable to be able to accurately model their transient behaviour and to predict the resulting currents and voltages in order to develop appropriate protection schemes, particularly for high power machines. Based on the multi-loop circuit method, a general mathematical model for a salient-pole synchronous machine with internal faults is established, and subsequently employed to simulate both the steady-state and transient behaviour for three different types of internal fault. Predicted results are validated by experimental measurements
Keywords
electrical faults; stators; synchronous machines; transient analysis; internal faults; internal stator winding faults; mathematical model; multi-loop circuit method; salient-pole synchronous machines; steady-state behaviour; transient behaviour;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings -
Publisher
iet
ISSN
1350-2352
Type
jour
DOI
10.1049/ip-epa:20020068
Filename
997805
Link To Document