• DocumentCode
    1277381
  • Title

    Optimal beamforming in ultrasound using the ideal observer

  • Author

    Abbey, Craig K. ; Nguyen, Nghia Q. ; Insana, Michael F.

  • Author_Institution
    Dept. of Psychol., Univ. of California, Santa Barbara, Santa Barbara, CA, USA
  • Volume
    57
  • Issue
    8
  • fYear
    2010
  • fDate
    8/1/2010 12:00:00 AM
  • Firstpage
    1782
  • Lastpage
    1796
  • Abstract
    Beamforming of received pulse-echo data generally involves the compression of signals from multiple channels within an aperture. This compression is irreversible, and therefore allows the possibility that information relevant for performing a diagnostic task is irretrievably lost. The purpose of this study was to evaluate information transfer in beamforming using a previously developed ideal observer model to quantify diagnostic information relevant to performing a task. We describe an elaborated statistical model of image formation for fixed-focus transmission and single-channel reception within a moving aperture, and we use this model on a panel of tasks related to breast sonography to evaluate receive-beamforming approaches that optimize the transfer of information. Under the assumption that acquisition noise is well described as an additive wide-band Gaussian white-noise process, we show that signal compression across receive-aperture channels after a 2-D matched-filtering operation results in no loss of diagnostic information. Across tasks, the matched-filter beamformer results in more information than standard delay-and-sum beamforming in the subsequent radio-frequency signal by a factor of two. We also show that for this matched filter, 68% of the information gain can be attributed to the phase of the matched-filter and 21% can be attributed to the amplitude. A 1-D matched filtering along axial lines shows no advantage over delay-andsum, suggesting an important role for incorporating correlations across different aperture windows in beamforming. We also show that a post-compression processing before the computation of an envelope is necessary to pass the diagnostic information in the beamformed radio-frequency signal to the final envelope image.
  • Keywords
    AWGN; acoustic pulses; acoustic signal processing; array signal processing; biomedical ultrasonics; echo; matched filters; ultrasonic focusing; ultrasonic imaging; 2D matched-filtering operation; acquisition noise; additive wide-band Gaussian white-noise process; breast sonography; diagnostic information; envelope image; fixed-focus transmission; ideal observer; image formation; information gain; information transfer; optimal ultrasound beamforming; pulse-echo data; radio-frequency signal; signal compression; single-channel reception; statistical model; Additive noise; Apertures; Array signal processing; Delay; Matched filters; Performance evaluation; Pulse compression methods; Radio frequency; Signal processing; Ultrasonic imaging; Algorithms; Computer Simulation; Models, Statistical; Monte Carlo Method; Normal Distribution; Signal Processing, Computer-Assisted; Ultrasonography, Mammary;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2010.1616
  • Filename
    5529466