DocumentCode
127815
Title
Practical industrial EUT testing in reverb chamber experiences, findings and practical observations on high amplitude immunity testing of industrial equipment in reverberation chamber
Author
Jensen, Per Thaastrup ; Mynster, Anders Pilgaard ; Behnke, Rasmus Brun
Author_Institution
Test & Consultancy, DELTA, Hoersholm, Denmark
fYear
2014
fDate
1-4 Sept. 2014
Firstpage
274
Lastpage
279
Abstract
Practical radiated immunity testing in a reverberation chamber requires testing activities different from classical radiated immunity tests performed according to IEC 61000-4-3. Especially investigatory tests like HALT (High Amplitude Limit Testing) analysis, where less than 12 stirrer positions are favorable in terms of speeding up the test, new strategies must be applied for the frequency scanning methodology and for the interpretation of the results. The practical testing has also revealed that the mains power adaptor may prove to be the Achilles heel of systems not comprising a dedicated power supply. The response and immunity of the mains adaptors has proved to be a limiting factor for the EMC properties of small data transmission systems. The paper presents the chamber behavior, the usefulness of stirrer stroke analysis as well as the observations and conclusions drawn from practical equipment testing.
Keywords
immunity testing; reverberation chambers; telecommunication power management; EMC properties; equipment testing; high amplitude immunity testing; high amplitude limit testing analysis; industrial EUT testing; industrial equipment; radiated immunity testing; reverberation chamber; Data communication; Immunity testing; Local area networks; Optical fiber cables; Reverberation chambers; EMC; HALT; HIRF; IT; WiFi; radiated immunity; reverberation; stirrer;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (EMC Europe), 2014 International Symposium on
Conference_Location
Gothenburg
Type
conf
DOI
10.1109/EMCEurope.2014.6930916
Filename
6930916
Link To Document