DocumentCode :
1278433
Title :
The spacing/height ratio of lighting units
Author :
McWhirter, H.R.S.
Volume :
78
Issue :
474
fYear :
1936
fDate :
6/1/1936 12:00:00 AM
Firstpage :
699
Lastpage :
704
Abstract :
In the present paper a method of evaluating the lightdispersing power of a light source is given, together with methods of calculating suitable values of spacing/height ratio from the polar distribution curve of the source. Optimum polar distribution curves corresponding to certain values of spacing/height ratio are shown, and information is given from which the optimum polar distribution curve corresponding to any value of spacing/height ratio may be drawn. A new criterion applicable to polar distribution curves and indicating their suitability for producing uniform illumination is suggested. New methods of testing lighting fittings are described. Suggestions are also made relative to the preparation of technical literature on the subject.
Keywords :
lamps; lighting;
fLanguage :
English
Journal_Title :
Electrical Engineers, Journal of the Institution of
Publisher :
iet
Type :
jour
DOI :
10.1049/jiee-1.1936.0107
Filename :
5317002
Link To Document :
بازگشت