DocumentCode :
1278973
Title :
Multi-target stimulator SSVEP using multi-frequency embedded with multi-phase encoding sequence
Author :
Kuo-Kai Shyu ; Po-Lei Lee ; Yu-Ju Liu ; Jyun-Jie Sie
Author_Institution :
Dept. of Electr. Eng., Nat. Central Univ., Jhongli, Taiwan
Volume :
48
Issue :
18
fYear :
2012
Firstpage :
1097
Lastpage :
1098
Abstract :
Presented is a novel coding method for steady-state visual evoked potential (SSVEP). To relax the limitations of SSVEP, the number of flash stimulators requires the same number of flashing frequencies for coding. However, the number of frequencies that may be required for stimulation is limited. This study proposes multi-frequencies embedded with the multi-phase flickering sequences stimulation method. In the experiments, the study considered SSVEPs induced by nine groups of light emitting diodes generated by only two frequencies. The proposed method of flickering sequences has been tested on five subjects to verify its feasibility. The average accuracy obtained was 87.3 ± 16.6± in the simulation test.
Keywords :
biomedical equipment; biomedical measurement; light emitting diodes; visual evoked potentials; coding method; flash stimulator number; flashing frequencies; light emitting diodes; multifrequency multiphase encoding sequence; multiphase flickering sequences stimulation method; multitarget stimulator SSVEP; steady state visual evoked potential;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el.2012.1325