DocumentCode :
1279858
Title :
Model-based methodology using modified sneak circuit analysis for power electronic converter fault diagnosis
Author :
Soman, R.R. ; Davidson, Euan M. ; McArthur, S.D.J. ; Fletcher, John E. ; Ericsen, T.
Author_Institution :
Dept. of Electron. & Electr. Eng., Univ. of Strathclyde, Glasgow, UK
Volume :
5
Issue :
6
fYear :
2012
fDate :
7/1/2012 12:00:00 AM
Firstpage :
813
Lastpage :
826
Abstract :
This study presents a novel research methodology and approach for diagnosing pertinent failures for power electronic converters. The concept of the generalised connection matrix for a sneak circuit analysis is used in this research. A novel modification to this process shown in this study produces a usable feature that provides unique signatures under fault scenarios and could be used to diagnose faults. The novelty lies in using component currents to form the generalised connection matrix. This study presents the results obtained using data collected from fault scenarios on a hardware set-up for the dc-dc buck converter.
Keywords :
DC-DC power convertors; fault diagnosis; network analysis; dc-dc buck converter; diagnose faults; fault scenarios; generalised connection matrix; hardware set-up; model-based methodology; modified sneak circuit analysis; pertinent failures; power electronic converter fault diagnosis;
fLanguage :
English
Journal_Title :
Power Electronics, IET
Publisher :
iet
ISSN :
1755-4535
Type :
jour
DOI :
10.1049/iet-pel.2011.0018
Filename :
6294940
Link To Document :
بازگشت