DocumentCode
1280708
Title
Squirrel-cage induction-motor core losses
Author
Spooner, T.
Author_Institution
Research Engineer, Westinghouse Electric & Mfg. Co., East Pittsburgh, Pa.
Volume
44
Issue
1
fYear
1925
Firstpage
32
Lastpage
37
Abstract
An experimental method is presented for segregating the various no-load losses of a squirrel-cage induction motor. It is shown that for insulated rotor bars the losses consist principally of stator fundamental-frequency losses, rotor surface losses and eddy-current losses in the rotor bars due to radial and tangential slot-leakage fluxes in the rotor slots caused by reluctance pulsations in the air gap between stator and rotor teeth. The pulsation losses vary about as the square of the air-gap induction and about as the 1.2 power of the frequency. The surface losses for the particular slots described are from ¼ to ⅓ of the total pulsation losses. The pulsation losses are approximately the same whether or not the rotor bars are connected by end rings, and are approximately equal to the stator fundamental-frequency losses.
fLanguage
English
Journal_Title
A.I.E.E., Journal of the
Publisher
ieee
ISSN
0095-9804
Type
jour
DOI
10.1109/JAIEE.1925.6538276
Filename
6538276
Link To Document