• DocumentCode
    1281197
  • Title

    Analytical estimation of measurement error performance of multiwavelength simultaneous monitoring circuit

  • Author

    Teshima, M. ; Koga, M.

  • Author_Institution
    NTT Opt. Network Syst. Labs., Kanagawa, Japan
  • Volume
    33
  • Issue
    19
  • fYear
    1997
  • fDate
    9/11/1997 12:00:00 AM
  • Firstpage
    1645
  • Lastpage
    1647
  • Abstract
    The authors estimate the frequency/power measurement error of a multiwavelength simultaneous monitoring circuit. The initial frequency measurement error is dominated by an imbalance in the bandwidths of the adjacent ports, compared with those of the optoelectrical conversion efficiency. The polarisation dependent power monitoring error is estimated to be ±0.18 and ±0.08 dB at the normalised-bandwidths of 0.4 and 0.6, respectively
  • Keywords
    frequency measurement; measurement errors; monitoring; optical variables measurement; power measurement; bandwidth; error; frequency measurement; multiwavelength simultaneous monitoring circuit; optoelectrical conversion efficiency; polarisation dependence; power measurement;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19971091
  • Filename