Abstract
A Compton backscatter tomographical imaging model with minimal constraints imposed on the measurement apparatus is presented as a potential contender for on-line portable imaging. The line-scan method based on scattered photon energy spectra can obtain a fairly high scan speed and spatial resolution. As such, radiation scattering imaging (or density reconstruction) is viewed as a nonlinear inverse problem. A solution algorithm is investigated for the density reconstruction problem with two criteria: maximum entropy and least-squares between the original measurement data projection due to reconstruction. Image reconstruction from simulations demonstrates the feasibility of the method
Keywords
Compton effect; backscatter; computerised tomography; gamma-ray applications; image reconstruction; inverse problems; least squares approximations; maximum entropy methods; Compton backscatter tomographical imaging model; density reconstruction; image reconstruction; least-squares; line-scan method; maximum entropy; multicriterion Compton backscatter imaging; nonlinear inverse problem; online portable imaging; radiation scattering imaging; scattered photon energy spectra; spatial resolution;
fLanguage
English
Journal_Title
Science, Measurement and Technology, IEE Proceedings -
Publisher
iet
ISSN
1350-2344
Type
jour
DOI
10.1049/ip-smt:19960279
Filename
553235
Link To Document