DocumentCode
1283491
Title
Pull-in characteristics of synchronous motors
Author
Shoults, D. ; Crary, S. ; H. Lauder, A.
Author_Institution
General Electric Co., Schenectady, N. Y.
Volume
54
Issue
12
fYear
1935
Firstpage
1385
Lastpage
1395
Abstract
The differential analyzer has proved its worth in solving various types of difficult problems, of which the determination of the pull-in characteristics of salient pole synchronous motors is typical; but even with the aid of this device it has been necessary in solving this problem to make several simplifying assumptions. The differential analyzer recently completed at the University of Pennsylvania, however, is sufficiently comprehensive in design so that few assumptions are necessary, and the major electrical transients and mechanical forces may be taken into account. Typical solutions obtained by means of this analyzer are presented herewith, together with practical pulling-into-step criteria.
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1935.6538822
Filename
6538822
Link To Document