Title :
The parameters optimization selection of Savitzky-Golay filter and its application in smoothing pretreatment for FTIR spectra
Author :
An-xin Zhao ; Xiao-jun Tang ; Zhong-hua Zhang ; Jun-hua Liu
Author_Institution :
State Key Lab. of Electr. Insulation & Power Equip., Xi´an Jiaotong Univ., Xi´an, China
Abstract :
Gas infrared spectrum should be reconstructed according to the collected spectral data by the spectrum detecting instrument which was used in the online gas Fourier transform infrared spectroscopy measurement. However, due to the influence of the factors such as ambient noise and the spectrum detecting instrument itself noise, spectrum reconstruction was mixed by noise and the results of subsequent analysis may be deviated from the true value. Therefore, the Savitzky-Golay filter was selected to smooth and denoise the spectrum in the procedure of the Fourier transform infrared spectra reconstruction. The main performance index of the Savitzky-Golay smoothing filter was decided by the polynomial order and frame size when the Savitzky-Golay filter was used for smoothing. Through the traversal search method, the relation between the main filter design index and the polynomial order, frame size were explored for the problems of the polynomial order and frame size selected arbitrary. And then, when the polynomial order and frame size should be used in the actual smoothing and filter, the above results can be choosed. According to the characteristics of the spectrum which was measured in this paper, the optimal polynomial order and frame size were selected as 8 and 11 respectively for smoothing and denoising the spectra data. The smoothing spectra for the actual spectra of 1% concentration of CH4 were very close coincidence to the standard spectra; At the same time, the converted absorbance of standard spectra, raw spectra and smoothed spectra for 1% concentration CH4 were 26.2720, 25.9017 and 26.2489 respectively, and the relative errors of the raw spectra and smoothed spectra were 1.4095% and 0.0880% respectively, in the second absorption peak area. The treatment effect was more apparent according to the method of the selection the polynomial order and frame size for the Savitzky-Golay smoothing filter, thereby a new method was provided for the Sa- itzky-Golay filter in other areas application.
Keywords :
Fourier transform spectroscopy; carbon compounds; infrared spectroscopy; signal denoising; signal reconstruction; smoothing methods; CH4; FTIR spectra; Fourier transform infrared spectra reconstruction; Savitzky-Golay smoothing filter; ambient noise; collected spectral data; converted absorbance; frame size; gas infrared spectrum; main filter design index; online gas Fourier transform infrared spectroscopy measurement; optimal polynomial order; raw spectra; second absorption peak area; smoothing spectra; spectra data; spectrum detecting instrument; spectrum reconstruction; traversal search method; treatment effect; Absorption; Cutoff frequency; Finite impulse response filters; Noise reduction; Polynomials; Smoothing methods; Fourier transform infrared spectroscopy; Savitzky-Golay smoothing filter; converted absorbance; smoothing and denoising; spectrum reconstruction;
Conference_Titel :
Industrial Electronics and Applications (ICIEA), 2014 IEEE 9th Conference on
Conference_Location :
Hangzhou
Print_ISBN :
978-1-4799-4316-6
DOI :
10.1109/ICIEA.2014.6931218