• DocumentCode
    1284343
  • Title

    Electrotactile Display with Real-Time Impedance Feedback Using Pulse Width Modulation

  • Author

    Kajimoto, Hiroyuki

  • Author_Institution
    Univ. of Electro-Commun., Chofu, Japan
  • Volume
    5
  • Issue
    2
  • fYear
    2012
  • Firstpage
    184
  • Lastpage
    188
  • Abstract
    An electrotactile display is a tactile interface composed of skin surface electrodes. The use of such a device is limited by the variability of the elicited sensation. One possible solution to this problem is to monitor skin electrical impedance. Previous studies revealed a correlation between impedance and threshold, but did not construct real-time feedback loops. In this study, an electrotactile display was constructed using a 1.45 μs feedback loop. Real-time pulse width modulation was proposed, and the relationship between skin resistance and absolute threshold was measured to find a function for determining a suitable pulse width from skin resistance. An evaluation experiment revealed that the proposed algorithm suppressed spatial variation and reduced temporal change.
  • Keywords
    bioelectric phenomena; biomedical electrodes; electric resistance; force feedback; haptic interfaces; neuromuscular stimulation; pulse width modulation; skin; absolute threshold; electrotactile display; elicited sensation variability; evaluation experiment; feedback loop; real-time pulse width modulation; skin electrical impedance monitoring; skin resistance; skin surface electrodes; spatial variation suppression; tactile interface; temporal change reduction; Current measurement; Electrodes; Fingers; Impedance; Resistance; Skin; Voltage measurement; Electrotactile display; impedance feedback; pulse width modulation; real-time feedback; two point discrimination.;
  • fLanguage
    English
  • Journal_Title
    Haptics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1939-1412
  • Type

    jour

  • DOI
    10.1109/TOH.2011.39
  • Filename
    5963668