DocumentCode
1284434
Title
Estimation of Stray Current From a DC-Electrified Railway and Impressed Potential on a Buried Pipe
Author
Ogunsola, Ade ; Mariscotti, Andrea ; Sandrolini, Leonardo
Author_Institution
Parsons Int., MENA, Abu Dhabi, United Arab Emirates
Volume
27
Issue
4
fYear
2012
Firstpage
2238
Lastpage
2246
Abstract
DC-electrified traction systems are a potential source of stray current that may corrode internal and external structures and installations. The stray current intensity depends on several factors (traction current, rail insulation, concrete mat and piers resistance), that are accounted for in the proposed model. The case of a viaduct and a victim-buried pipeline is considered in detail, and the estimated impressed voltage on the pipe is compared successfully with experimental results.
Keywords
electromagnetic interference; pipelines; railway electrification; traction; DC-electrified railway; DC-electrified traction systems; concrete mat; external structures; internal structures; piers resistance; rail insulation; stray current estimation; stray current intensity; traction current; victim-buried pipeline; DC machines; Degradation; Electromagnetic interference; Insulation life; Power distribution; Predictive models; Resistance; Corrosion; electromagnetic conductive interference; guideway transportation power systems; power distribution electromagnetic interference; stray current;
fLanguage
English
Journal_Title
Power Delivery, IEEE Transactions on
Publisher
ieee
ISSN
0885-8977
Type
jour
DOI
10.1109/TPWRD.2012.2211623
Filename
6301811
Link To Document