DocumentCode :
1284434
Title :
Estimation of Stray Current From a DC-Electrified Railway and Impressed Potential on a Buried Pipe
Author :
Ogunsola, Ade ; Mariscotti, Andrea ; Sandrolini, Leonardo
Author_Institution :
Parsons Int., MENA, Abu Dhabi, United Arab Emirates
Volume :
27
Issue :
4
fYear :
2012
Firstpage :
2238
Lastpage :
2246
Abstract :
DC-electrified traction systems are a potential source of stray current that may corrode internal and external structures and installations. The stray current intensity depends on several factors (traction current, rail insulation, concrete mat and piers resistance), that are accounted for in the proposed model. The case of a viaduct and a victim-buried pipeline is considered in detail, and the estimated impressed voltage on the pipe is compared successfully with experimental results.
Keywords :
electromagnetic interference; pipelines; railway electrification; traction; DC-electrified railway; DC-electrified traction systems; concrete mat; external structures; internal structures; piers resistance; rail insulation; stray current estimation; stray current intensity; traction current; victim-buried pipeline; DC machines; Degradation; Electromagnetic interference; Insulation life; Power distribution; Predictive models; Resistance; Corrosion; electromagnetic conductive interference; guideway transportation power systems; power distribution electromagnetic interference; stray current;
fLanguage :
English
Journal_Title :
Power Delivery, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8977
Type :
jour
DOI :
10.1109/TPWRD.2012.2211623
Filename :
6301811
Link To Document :
بازگشت