    Evaluation of a 16:3 Signal Multiplexor to Acquire Signals From a SPM Array With Dual and Single Layer LYSO Crystal Blocks

  • Author

    Thompson, Christopher J. ; Goertzen, Andrew L.

  • Author_Institution
    Montreal Neurological Inst., McGill Univer sity. Montreal, Montreal, QC, Canada
  • Volume
    58
  • Issue
    5
  • fYear
    2011
  • Firstpage
    2175
  • Lastpage
    2180
  • Abstract
    For many years most PET scanners have used a large number of crystals with some form of light sharing technique to couple them to four photo-multiplier tubes (PMT). While the resolution of the scanners was improved by using a larger number of smaller crystals, the PMT size had remained about the same since it is not practical to make PMTs very small. Avalanche photo-diodes (APD) and silicon photo-multipliers (SPM) are now replacing PMTs in small animal PET scanners and in MR-PET scanners in which PMTs are not practical due to their sensitivity to magnetic fields. In this paper we study the performance of a dual layer PET detector consisting a 4 × 4 array of 3.3 mm × 3.3 mm LYSO crystals in the lower layer and an upper offset layer of 3 × 3 crystals coupled to a SensL SPMArray4 4 × 4 array of SPMs. A single layer array of 1.68 mm × 1.68 mm crystals is also studied. The standard SensL pre-amplifier and evaluation board were used to process the signals. The 16 outputs of the evaluation board were connected directly to 16 ADC channels or through a 16:3 multiplexor which uses simple summing amplifiers to provide bipolar X and Y signals as well as the sum of all inputs. In this case only 3 ADCs are required to encode the signals. In both cases a crystal identification map is produced in software. The use of the multiplexor has a negligible effect on the size of each crystal´s foot-print or its energy resolution. We introduce the concept of “resolvability index” (RI) to compare the size of each crystal´s foot-print and distance to its neighbour. Our results suggest that the RI with the multiplexed SPM readout is comparable to that of a conventional PS-PMT readout, and superior to that of conventional PET detectors with four PMTs. We anticipate that even smaller crystals could be used on the SPM making this a good choice for small animal PET scanners.
  • Keywords
    amplifiers; analogue-digital conversion; avalanche photodiodes; high energy physics instrumentation computing; nuclear electronics; photomultipliers; positron emission tomography; readout electronics; silicon radiation detectors; ADC; MR-PET scanner; PS-PMT readout system; SPM array; SensL SPMArray; avalanche photodiode; dual layer PET detector; light sharing technique; photomultiplier tube; resolvability index; signal multiplexor evaluation; silicon photomultiplier; single layer LYSO crystal blocks; standard SensL preamplifler; Arrays; Crystals; Detectors; Multiplexing; Positron emission tomography; Resistors; Block detector; PET; multiplexed output; silicon photomultiplier;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2011.2160202
  • Filename
    5963748