• DocumentCode
    1284802
  • Title

    An oscillographic technique for measurements in a network analyser

  • Author

    Myers, D.M. ; Clothier, W.K.

  • Volume
    85
  • Issue
    515
  • fYear
    1939
  • fDate
    11/1/1939 12:00:00 AM
  • Firstpage
    639
  • Lastpage
    645
  • Abstract
    Two new methods of measurement in alternating-current networks are described. Each method involves the use of a cathode-ray oscillograph, together with a precision-type phaseshifting transformer, a calibrated potential divider, and amplifying equipment. One, a null method, is capable of very high accuracy. The other, although not capable of the same degree of accuracy, has certain definite advantages. It is particularly useful, for instance, in the analysis of networks containing elements with variable parameters, and in the investigation of transient phenomena in networks. The manner of operation of the measuring equipment is illustrated by a series of photographic records.
  • Keywords
    cathode-ray oscilloscopes; circuit theory; distribution networks; electric current measurement; power measurement; voltage measurement;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Journal of the Institution of
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/jiee-1.1939.0223
  • Filename
    5318528