Water-Level Control. Control of the water level in a model of the Cape Cod (Mass.) Canal and the automatic recording of water level at several points during studies of flow were accomplished electrically by utilizing the capacitance between the water itself and a plate suspended above it, together with suitable vacuum-tube amplifiers, grid-controlled arc-discharge tubes, and Selsyn motors (pages 237–44).