DocumentCode
1285436
Title
Calorimetric measurement of dielectric losses in solids
Author
Race, H. ; Leonard, S.
Author_Institution
Both of the General Electric Company, Schenectady, N. Y.
Volume
55
Issue
12
fYear
1936
Firstpage
1347
Lastpage
1356
Abstract
A new transient calorimetric method for measurement of dielectric losses in solids at 10,000 volts and 1,000 kilocycles, is described in this paper and experimental data obtained by this method are presented. A steady-state method also is described and a direct comparison between the results obtained by the 2 methods is given. The absolute value of loss factor (0.0009) determined for quartz shows exact agreement between the 2 methods. The transient method is shown to reduce the time of making calorimetric measurements on solid materials from hours to minutes. Results of tests on 15 samples, including 6 different low-loss materials, show that the absolute values of losses in these particular materials are of the order of magnitude determined by previous low-voltage high-frequency measurements. It is thought that the transient calorimeter technique can be readily extended to ultra-high frequencies.
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1936.6539235
Filename
6539235
Link To Document