DocumentCode
1285827
Title
A comparative study on the starting methods of three phase wound-rotor induction motors. I
Author
Hamouda, R.M. ; Alolah, A.I. ; Badr, M.A. ; Abdel-Halim, M.A.
Author_Institution
Dept. of Electr. Eng., King Saud Univ., Riyadh, Saudi Arabia
Volume
14
Issue
4
fYear
1999
fDate
12/1/1999 12:00:00 AM
Firstpage
918
Lastpage
922
Abstract
This paper presents a comparative study on the starting performance of three phase wound-rotor induction motors under different methods of starting. These methods are online direct starting, variable rotor resistance starting and double feed starting. In the double feed starting, the rotor winding is connected in parallel with the stator winding across the supply for a predetermined short period. By this connection, the motor produces an extremely high starting torque. For carrying out the investigations sought, a rigorous state space mathematical model has been developed and simulated. The effect of torsional dynamics has been taken into considerations
Keywords
induction motors; machine theory; rotors; starting; state-space methods; stators; torsion; double feed starting; high starting torque production; online direct starting; parallel winding connection; rotor winding; starting methods comparison; starting performance; state-space mathematical model; stator winding; three phase wound-rotor induction motor; torsional dynamics; variable rotor resistance starting; Capacitors; Educational institutions; Feeds; Induction motors; Rotors; State-space methods; Stator windings; Synchronous motors; Torque; Voltage;
fLanguage
English
Journal_Title
Energy Conversion, IEEE Transactions on
Publisher
ieee
ISSN
0885-8969
Type
jour
DOI
10.1109/60.815008
Filename
815008