DocumentCode
1286026
Title
On the measurement of conduction current in AC thin-film electroluminescent display devices
Author
Singh, Vijay P. ; Morton, David C.
Author_Institution
Dept. of Electr. Eng., Texas Univ., El Paso, TX, USA
Volume
11
Issue
12
fYear
1990
Firstpage
573
Lastpage
575
Abstract
Estimates are obtained for errors associated with the use of a capacitive bridge method for the measurement of the conduction current-time waveform in AC thin-film electroluminescent display devices. The error is a function of the shape and the slew rate of the excitation voltage pulses and can be quite large. In general, the bridge method underestimates the value of conduction current. An improved technique for measuring the current waveform is outlined. The proposed method is more accurate and more generally applicable.<>
Keywords
bridge instruments; electric current measurement; electroluminescent displays; AC thin-film electroluminescent display devices; conduction current; current-time waveform; excitation voltage pulses; slew rate; Bridge circuits; Current measurement; Dielectrics; Displacement measurement; Displays; Electroluminescent devices; Phosphors; Pulse measurements; Thin film devices; Threshold voltage;
fLanguage
English
Journal_Title
Electron Device Letters, IEEE
Publisher
ieee
ISSN
0741-3106
Type
jour
DOI
10.1109/55.63043
Filename
63043
Link To Document