DocumentCode
1286103
Title
Increased sensitivity of capacitive couplers for in-service PD measurement in rotating machines
Author
Zhu, H. ; Green, V. ; Sasic, M. ; Halliburton, S.
Author_Institution
ADWEL Int. Ltd., Toronto, Ont., Canada
Volume
14
Issue
4
fYear
1999
fDate
12/1/1999 12:00:00 AM
Firstpage
1184
Lastpage
1192
Abstract
Capacitive couplers are widely used as sensors for in-service/online partial discharge (PD) measurement in rotating machines. They are permanently installed in operating generators and motors to detect partial discharges. The capacitive couplers traditionally used for PD detection on rotating machines have been 80 pF. Recently it has been found that higher detection sensitivity can be obtained by increasing capacitance of 80 pF couplers. This paper presents theoretical analysis, laboratory tests and field test experience to compare traditional 80 pF couplers and higher-capacitance couplers for in-service PD measurement in rotating machines. The frequency bandwidth of various capacitive couplers is characterized and analyzed in relation to the PD detection sensitivity. This investigation concludes capacitive couplers with a higher capacitance than 80 pF are more sensitive for in-service PD measurement in rotating machines. More partial discharges and higher PD magnitudes can be acquired by using higher capacitance couplers than 80 pF couplers
Keywords
capacitive sensors; electric machines; insulation testing; machine insulation; machine testing; partial discharge measurement; 80 pF; capacitive couplers; field tests; generators; in-service PD measurement; laboratory tests; motors; partial discharge detection; rotating machines; sensitivity improvement; Capacitance; Capacitive sensors; Couplers; Frequency; Laboratories; Partial discharge measurement; Partial discharges; Rotating machines; Rotation measurement; Testing;
fLanguage
English
Journal_Title
Energy Conversion, IEEE Transactions on
Publisher
ieee
ISSN
0885-8969
Type
jour
DOI
10.1109/60.815045
Filename
815045
Link To Document