DocumentCode
1286247
Title
Simulation of internal faults in synchronous generators
Author
Megahed, A.I. ; Malik, O.P.
Author_Institution
Dept. of Electr. & Comput. Eng., Calgary Univ., Alta., Canada
Volume
14
Issue
4
fYear
1999
fDate
12/1/1999 12:00:00 AM
Firstpage
1306
Lastpage
1311
Abstract
An internal fault in the armature winding of a synchronous generator occurs due to the breakdown of the winding insulation. In this paper, a method for simulating internal faults in synchronous generators, using direct phase quantities, is described. Simulation results showing the fault currents, during a single phase to ground fault and a two phase to ground fault, are presented
Keywords
electric breakdown; electrical faults; machine insulation; machine theory; machine windings; synchronous generators; armature winding; direct phase quantities; fault currents; internal faults simulation; single phase-to-ground fault; synchronous generators; two phase-to-ground fault; winding insulation breakdown; Circuit faults; Coils; Computational modeling; Fault currents; Machine windings; Protection; Short circuit currents; Stator windings; Synchronous generators; Synchronous machines;
fLanguage
English
Journal_Title
Energy Conversion, IEEE Transactions on
Publisher
ieee
ISSN
0885-8969
Type
jour
DOI
10.1109/60.815064
Filename
815064