• DocumentCode
    1286247
  • Title

    Simulation of internal faults in synchronous generators

  • Author

    Megahed, A.I. ; Malik, O.P.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Calgary Univ., Alta., Canada
  • Volume
    14
  • Issue
    4
  • fYear
    1999
  • fDate
    12/1/1999 12:00:00 AM
  • Firstpage
    1306
  • Lastpage
    1311
  • Abstract
    An internal fault in the armature winding of a synchronous generator occurs due to the breakdown of the winding insulation. In this paper, a method for simulating internal faults in synchronous generators, using direct phase quantities, is described. Simulation results showing the fault currents, during a single phase to ground fault and a two phase to ground fault, are presented
  • Keywords
    electric breakdown; electrical faults; machine insulation; machine theory; machine windings; synchronous generators; armature winding; direct phase quantities; fault currents; internal faults simulation; single phase-to-ground fault; synchronous generators; two phase-to-ground fault; winding insulation breakdown; Circuit faults; Coils; Computational modeling; Fault currents; Machine windings; Protection; Short circuit currents; Stator windings; Synchronous generators; Synchronous machines;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/60.815064
  • Filename
    815064