• DocumentCode
    1289216
  • Title

    Measuring Changes of Movement Dynamics During Robot-Aided Neurorehabilitation of Stroke Patients

  • Author

    Colombo, Roberto ; Sterpi, Irma ; Mazzone, Alessandra ; Delconte, Carmen ; Minuco, Giuseppe ; Pisano, Fabrizio

  • Author_Institution
    Service of Rehabilitation Eng., Salvatore Maugeri Found., Pavia, Italy
  • Volume
    18
  • Issue
    1
  • fYear
    2010
  • Firstpage
    75
  • Lastpage
    85
  • Abstract
    The aim of this study was to describe in detail a new method, called normalized force control parameter (nFCP), to measure changes in movement dynamics obtained during robot-aided neurorehabilitation, and to evaluate its ability to estimate the clinical scales. The study was conducted in a group of 18 subjects after chronic stroke who underwent robot therapy of the upper limb. We used two different measures of movement dynamics to assess patients´ performance during each session of training: the nFCP and force directional error (FDE), both measuring the directional error of the patient-exerted force applied to the end-effector of the robot device. Both metrics exhibited significant changes over the three-week course of treatment. The comparison between nFCP and FDE slopes showed a significant and high correlation (r = 0.79; p < 0.001), indicating that the two parameters are closely correlated. The FDE informed on the direction of the force error, while the nFCP showed a better performance in predicting the clinical scale values. Assessment of the time course of recovery showed that nFCP, FDE and the movement smoothness improved quickly at first and then plateaued, while steady gains in mean velocity of movement took place over a longer time course. These data may be helpful to the therapist in developing more effective robot-based therapy protocols.
  • Keywords
    biomechanics; brain; diseases; electromyography; force control; medical robotics; neurophysiology; patient rehabilitation; patient treatment; EMG recording; chronic stroke; force directional error; movement dynamics; normalized force control parameter; robot therapy; robot-aided neurorehabilitation; stroke patients; time 3 week; upper limb; Force control; motor recovery; neurorehabilitation; robot therapy; stroke; Diagnosis, Computer-Assisted; Female; Humans; Male; Middle Aged; Movement; Movement Disorders; Physical Therapy Modalities; Reproducibility of Results; Robotics; Sensitivity and Specificity; Stroke; Therapy, Computer-Assisted;
  • fLanguage
    English
  • Journal_Title
    Neural Systems and Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1534-4320
  • Type

    jour

  • DOI
    10.1109/TNSRE.2009.2028831
  • Filename
    5196800