• DocumentCode
    1289320
  • Title

    Average and hysteresis current-controlled three-phase three-level unity power factor rectifier operation and performance

  • Author

    Maswood, A.I. ; Al-Ammar, E. ; Liu, Frank

  • Author_Institution
    Lab. for Clean Energy Res., Nanyang Technol. Univ., Singapore, Singapore
  • Volume
    4
  • Issue
    7
  • fYear
    2011
  • Firstpage
    752
  • Lastpage
    758
  • Abstract
    Three-phase three-level rectifier (TPTL) is popular in present days for high-power application owing to its low blocking-voltage stress on the power switches (half of dc-link voltage). Such a rectifier can also operate as unity power factor (PF) converter as presented in this work. The rectifier input current controller can be operated with either fixed frequency or random frequency both with their advantages and shortcomings. In this study, the current controller is implemented with: (a) conventional hysteresis current control (random frequency) and (b) average current control (fixed frequency). The design issues and the performance of the two current modulation strategies are investigated and compared. Rectifier performance parameter, that is, THD and PF are evaluated and confirmed through hardware prototype results.
  • Keywords
    electric current control; harmonic distortion; power convertors; power factor; rectifying circuits; THD; current modulation strategy; hysteresis current-controlled rectifier; low blocking-voltage stress; power switches; random frequency; three-phase three-level unity power factor rectifier; total harmonic distortion; unity power factor converter;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IET
  • Publisher
    iet
  • ISSN
    1755-4535
  • Type

    jour

  • DOI
    10.1049/iet-pel.2010.0189
  • Filename
    5972002