• DocumentCode
    1295027
  • Title

    Intrinsic safety for electronic instrumentation in hazardous areas

  • Author

    Hickes, Willis F.

  • Author_Institution
    The Foxboro Co., Foxboro, Mass.
  • Volume
    82
  • Issue
    4
  • fYear
    1963
  • fDate
    4/1/1963 12:00:00 AM
  • Firstpage
    253
  • Lastpage
    257
  • Abstract
    The intrinsic safety approach for making electric equipment safe in hazardous areas is to limit energy levels to values too low to cause ignition. Safe energy levels are adequate for instrumentation. Advantages include elimination of cumbersome explosion-proof housings, ease of servicing, and equipment that is more nearly foolproof. Code status both here and abroad is reviewed
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1963.6541055
  • Filename