DocumentCode
1296108
Title
Generalized injected voltage method for the establishment of multidecade inductive voltage divider standard
Author
Zhang, G.-M. ; Zhao, F.-Z.
Author_Institution
Nat. Inst. of Metrol. of China. Beijing, China
Issue
1
fYear
1987
fDate
3/1/1987 12:00:00 AM
Firstpage
9
Lastpage
12
Abstract
A generalized injected voltage (GIV) method for a multidecade inductive voltage divider (IVD) is described. This method can be used for calibration multidecade IVDs including not only each individual decade´s settings but also combinations of decade settings in succession. The uncertainty of this method is estimated to be within 2×10-8 at 1 kHz and 2×10-7 at 10 kHz. An example of complete self-calibration for first and second decades of a multidecade IVD by the GIV method, and the corresponding data are given.
Keywords
calibration; measurement standards; voltage dividers; 1 kHz; 10 kHz; decade settings; generalized injected voltage; measurement standards; multidecade inductive voltage divider; self-calibration; Calibration; Data processing; Electric potential; Metrology; Silicon; Standards; Uncertainty;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1987.6312621
Filename
6312621
Link To Document