Title : 
On the development of large Josephson series arrays for voltage standards of high precision
         
        
            Author : 
Niemeyer, Jürgen
         
        
            Author_Institution : 
Physikalisch-Technische Bundesanstalt, 3300 Braunschweig, Germany
         
        
        
        
            fDate : 
6/1/1987 12:00:00 AM
         
        
        
        
            Abstract : 
It is possible to obtain stable reference voltages of more than 1 V for high-precision voltage standards by generating microwave-induced zero current constant voltage steps in the dc characteristic of large series arrays of Josephson tunnel junctions. An array voltage of 1 V can be reproduced within a few parts in 1010 at room temperature. The current dependence of the step voltage at the 1-V level over a stepwidth of 20 μA is less than 7 × 10−13V.
         
        
            Keywords : 
Calibration; Electrodes; Junctions; Microwave circuits; Radio frequency; Standards;
         
        
        
            Journal_Title : 
Instrumentation and Measurement, IEEE Transactions on
         
        
        
        
        
            DOI : 
10.1109/TIM.1987.6312680