• DocumentCode
    1297059
  • Title

    Analyzing the Windkessel Model as a Potential Candidate for Correcting Oscillometric Blood-Pressure Measurements

  • Author

    Barbé, Kurt ; Van Moer, Wendy ; Schoors, Danny

  • Author_Institution
    Dept. of Fundamental Electr. & Instrum., Vrije Univ. Brussel, Brussels, Belgium
  • Volume
    61
  • Issue
    2
  • fYear
    2012
  • Firstpage
    411
  • Lastpage
    418
  • Abstract
    Developing a good model for oscillometric blood-pressure measurements is a hard task. This is mainly due to the fact that the systolic and diastolic pressures cannot be directly measured by noninvasive automatic oscillometric blood-pressure meters (NIBP) but need to be computed based on some kind of algorithm. This is in strong contrast with the classical Korotkoff method, where the diastolic and systolic blood pressures can be directly measured by a sphygmomanometer. Although an NIBP returns results similar to the Korotkoff method for patients with normal blood pressures, a big discrepancy exist between both methods for severe hyper- and hypotension. For these severe cases, a statistical model is needed to compensate or calibrate the oscillometric blood-pressure meters. Although different statistical models have been already studied, no immediate calibration method has been proposed. The reason is that the step from a model, describing the measurements, to a calibration, correcting the blood-pressure meters, is a rather large leap. In this paper, we study a “databased” Fourier series approach to model the oscillometric waveform and use the Windkessel model for the blood flow to correct the oscillometric blood-pressure meters. The method is validated on a measurement campaign consisting of healthy patients and patients suffering from either hyper- or hypotension.
  • Keywords
    Fourier analysis; biomedical equipment; blood; blood flow measurement; blood pressure measurement; calibration; haemorheology; medical disorders; Windkessel model; calibration; classical Korotkoff method; correcting oscillometric blood-pressure measurements; databased Fourier series; diastolic pressure; hypertension; hypotension; noninvasive automatic oscillometric blood-pressure meters; oscillometric waveform; sphygmomanometer; systolic pressure; Blood; Blood pressure; Calibration; Heart; Mathematical model; Medical services; Pressure measurement; Biomedical modeling; Fourier series; Windkessel model; calibration; inverse problem; oscillometric blood-pressure measurements; signal reconstruction;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2011.2161933
  • Filename
    5983441