DocumentCode
1297742
Title
Flashing of railway motors caused by brush jumping
Author
Hellmund, R.E.
Author_Institution
Westinshouse Elec. and Mfg. Co., E. Pittsburgh, Pa.
Volume
54
Issue
11
fYear
1935
Firstpage
1178
Lastpage
1185
Abstract
Theories and concepts developed in connection with circuit rupturing by switches and circuit breakers are used to analyze the factors involved in the flashing of railway motors. The investigation is limited to cases where flashing is caused by brush jumping, which occurs principally with railway motors. Voltage conditions as applying at the commutator circumference and as affecting the sustenance of an arc are studied for varying designs of main poles with different ratios of armature ampere turns to field ampere turns. The effect of load current and speed is subsequently taken into account. Actual test results are compared with the theories outlined. Finally, the modifying effect of certain secondary phenomena is discussed.
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1935.6541561
Filename
6541561