DocumentCode :
1298123
Title :
Stability requirements for multiple laser diode extended range interferometry
Author :
Meggitt, B.T. ; Cormier, A.J.
Author_Institution :
Sira Ltd., Chislehurst
Volume :
24
Issue :
6
fYear :
1988
fDate :
3/17/1988 12:00:00 AM
Firstpage :
352
Lastpage :
353
Abstract :
The effects of wavelength instabilities on the performance of a multiwavelength heterodyne interferometer are treated theoretically in relation to a multisource system. The analysis predicts that a geometrically progressive synthetic wave set is the ideal configuration, and that an optimum number of wavelengths exists that minimises the stability requirements of the sources
Keywords :
distance measurement; light interferometry; measurement by laser beam; semiconductor junction lasers; stability; extended range interferometry; geometrically progressive synthetic wave set; ideal configuration; multiple laser diode; multisource system; multiwavelength heterodyne interferometer; ranging instruments; semiconductor lasers; wavelength instabilities;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
Filename :
8213
Link To Document :
بازگشت