  • Abstract
    The goal of this work is to present a standstill method to identify induction generator parameters typically used in wind generation. The method is based on the frequency domain identification of direct, quadrature and zero sequence frequency responses to identify five parameters of the machine. These tests replace the conventional locked-rotor and no-load tests. The magnetising inductance saturation problem is optimally tackled by means of sensitivity analysis. The proposed method has been validated using non-linear time-domain simulations of a 660 kW wind generator and the experimental results are validated on a laboratory test bed whose parameters were already known by conventional tests.
  • Keywords
    asynchronous generators; frequency response; parameter estimation; sensitivity analysis; time-domain analysis; wind power plants; frequency domain identification; in situ electrical parameter identification method; induction wind generators; magnetising inductance saturation problem; nonlinear time-domain simulations; power 660 kW; quadrature frequency responses; sensitivity analysis; zero sequence frequency responses;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IET
  • Publisher
    iet
  • ISSN
    1751-8660
  • Type

    jour

  • DOI
    10.1049/iet-epa.2010.0236
  • Filename
    5986773