DocumentCode
1300296
Title
Microchannel plate intensifier response in transverse magnetic field
Author
Allison, S.W. ; Ramos, P.A. ; Gillies, G.T.
Author_Institution
Dept. of Nucl. Eng., Eng. Phys., Virginia Univ., Charlottesville, VA, USA
Volume
26
Issue
12
fYear
1990
fDate
6/7/1990 12:00:00 AM
Firstpage
770
Lastpage
772
Abstract
Gain and image shift measurements are presented for a proximity-focused microchannel plate (MCP) image intensifier as a function of magnetic field (to 0.12 T) transverse to the optical axis. A simple model involving the angle of electron deflection, end-spoiled channel length and effective open area is described which agrees with the experiment.
Keywords
electron optics; focusing; image intensifiers; magnetic fields; 0.12 T; MCP; effective open area; electron deflection angle; end-spoiled channel length; gain measurements; image intensifier; image shift measurements; intensifier response; microchannel plate; model; proximity-focused; transverse magnetic field;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19900503