  • Abstract
    Linkage transfer phenomenon, which exists in the opening process of the operating mechanism of the molded case circuit breaker MCCB, is introduced. The influence of the linkage transfer position on the behavior of the mechanism is analyzed. According to the analysis result, the linkage transfer position of an actual operating mechanism is improved with virtual prototype technology software ADAMS. Simulation and experiment results show that after improvement, the opening time of the mechanism is shortened by about 1 ms. Short-circuit tests demonstrate that the operating mechanism with its linkage transfer position improved is helpful for enhancing the interruption performance of MCCB while breaking the low-current faults.
  • Keywords
    circuit breakers; short-circuit currents; ADAMS; MCCB; linkage transfer position; low current faults; molded case circuit breaker; short circuit tests; virtual prototype technology software; Couplings; Damping; Downlink; Friction; Integrated circuit modeling; Mathematical model; Software; Interruption performance; linkage transfer position; operating mechanism; virtual prototype technology (VPT);
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/TPWRD.2010.2059049
  • Filename
    5551264